If there are wires landed on the J2 fire loop, check the LED2. If it is not lit, the fire loop is open:

When fire loop is closed:

New price increase July 18, 2025
|
The arm may have been installed wrong. To reinstall the arm, remove from spindle and put rocker switch to hold open. Put door at 90 degrees to frame and reinstall the arm as per instructions.
You may also have a cam orientation issue on top of the motor gear box where the back check and latch limit switches are controlled. Follow the chart below to re-position cam:
The key is turned to the armed position, but the device does not sound when the door opens and the door prop time expires.
Handed to wrong side.
Unplug and reinsert battery, 4 chirps is in door prop mode.
5 chirps, the unit is not handed. Confirm the magnet is aligned correctly.
Disarm the device by turning your key clockwise. Look on the circuit board, there are to metal prongs with white lettering saying ‘Mag Handing’. Short them together using metal like a screwdriver or the key. The unit should chirp 5 times. Reinstall the device with the door open, turn device to on, and close door. You should hear 1 chirp and then the device is ready.
If JP1 is cut on the board, the unit is made to mount on the wall and use a external magnetic switch.
The likely causes are that either:
– Your door contact is not activating when the door closes. In this case, your device will not arm if the contact wires are removed from the device.
– Electric power was applied across terminals 5 and 6. In this case, your device will still arm after the door contact wires are removed from the device.
Two possible reasons:
1. Tamper plunger is not being held back by the screw on the upper left of the front of the device. Make sure the unit is mounted and the top left tamper screw is installed. Check That the security plunger is engaging the security micro switch on the back of the PCB.
2. Set to auto rearm(non-extended bypass) and the magnet on the frame not aligned properly. Isolate the device by using a jumper to simulate the door closure in inputs 5 and 6. If your device works, then check you magnet switch continuity. The magnetic switch is a closed contact when the door is closed and opens when the door is opened. These two wires should be connected to terminals 5 & 6.
The status indicator is set to “on”. The battery life when using the status indicator will only get up to 3 months.
This can be turned off by the slide switch on the circuit board as shown in the picture below. Remove the battery first, adjust the switch, replace the battery and rearm.
With status off, battery life can last for up to 12 months.
Note: Use name brand alkaline battery. If unit has gotten wet, it will drain the battery.