All LEDs and bar display are fully on reset by unplugging both modular cables and plugging the control board back in first, then the display board.
If LEDs return to normal, test by adding time and opening and closing door should reset the display. Opening the door should sound the alarm with no time entered. This would be working correctly.
Display has 1 bar and can’t clear. Reset by unplugging both modular cables and plugging the control board back in first and then the display board. If this doesn’t correct it then check to see that the micro switch being released. If it is released then Cycle power to reset, if no help. Replacement board kit is 104393. This includes all 3 circuit boards and the modular cable.
New Braunfels, TX — Detex Corporation is honored to announce its nomination for the Outstanding…
Regular door hardware maintenance is essential for ensuring safety, security, and compliance with building codes.…
If there are wires landed on the J2 fire loop, check the LED2. If it…
The arm may have been installed wrong. To reinstall the arm, remove from spindle and…
Refer to the installation instructions and follow the instructions