Categories: EAX-500 FAQFAQ

The magnet only works on one side of the device

Disarm the device by turning your key clockwise. Look on the circuit board near the sticker saying “500”, there are two metal prongs with white lettering near them saying ‘Mag Handing’. Short them together using something metal like a screwdriver or a key. The unit should beep 5 times.  Reinstall the device with the door open, arm by turning the key counter-clockwise and close the door. You should hear 1 chirp and then the device should start the 15 second arming delay indicated by rapid flashing of green light, followed by 3 chirps, indicating that it is armed.

If JP1 is cut on the board, the unit is made to mount on the wall and use a external magnetic switch.

Please refer to the installation instructions for more information on how to re-hand your device

Aubrey Mahan

Recent Posts

Detex Nominated for Outstanding Manufacturing Mentor Award by Skillpoint Alliance

New Braunfels, TX — Detex Corporation is honored to announce its nomination for the Outstanding…

2 weeks ago

The Importance of Door Hardware Maintenance

Regular door hardware maintenance is essential for ensuring safety, security, and compliance with building codes.…

3 weeks ago

I have input power, but no output power

If there are wires landed on the J2 fire loop, check the LED2. If it…

1 month ago

My latch light never comes on. It stays on close speed

The arm may have been installed wrong. To reinstall the arm, remove from spindle and…

1 month ago

How do I change the door prop time?

Refer to the installation instructions and follow the instructions

1 month ago