Exit Alarm with 9V Battery Option (EB) Available with Detex V40 Series exit devices. Includes 100 decibel, 9-volt battery alarm, LED display and latch bolt security monitoring.
|
|
 |
|
Exit Alarm with 9V Battery Weatherized (EBxW) Available with Detex V40 Series weatherized exit devices. Includes 100 decibel 9-volt battery alarm, LED display, remote signal output and bypass input. All components are weatherized for harsh environments.
|
|
 |
|
Electric Dogging (ED) Available for V40 Series exit devices to provide push-pull operation when activated, electrically maintaining push pad and latch bolt retraction until deactivated by a switch or fire alarm input.
|
|
 |
|
Delayed Egress (EE) Available for V40 Series exit devices with 15 second delay and 100 decibel alarm. The Value Series EE option includes a regulated and filtered power supply as a standard feature.
|
|
 |
|
Alarmed Rim Exit Device - Hardwired (EH) Available with Detex V40 Series exit devices. Includes 100 decibel, 12VAC powered alarm with 9-Volt battery backup. LED display and latch bolt security monitoring.
|
|
 |
|
Alarmed Rim Exit Device with Remote Signal & Remote Bypass (EHxR) Available with Detex V40 Series exit devices. Includes 100 decibel, 12VAC powered alarm with 9-Volt battery backup, LED display, remote signal output, bypass input and latch bolt security monitoring.
|
|
 |
|
Electric Integration (EI) Available for V40 Series exit devices to interface with a Detex 800 Series logic controller and other manufacturers' electrified hardware for a variety of customer specified uses.
|
|
 |
|
Delayed Egress with Magnetic Locking (EM) Secure 2-point locking (1400 lb with the panic device and 1500 lb with the electromagnetic lock) with 15 second delay and 100 decibel alarm. The Value Series EM option includes a regulated and filtered power supply as a standard feature.
|
|
 |
|
Electric Latch Retraction (ER) Available for Detex V40 Series exit devices to be used where remote unlocking, remote dogging, access control or automatic door operation is desired.
V40 ER Option Information
|
|
 |
|
Electric Switching (ES) Available for V40 Series exit devices to signal an alarm, shunt power to an electromagnetic lock or for a variety of uses requiring deadlatch monitoring. Push pad monitoring for egress and outside trim monitoring for access
|
|
 |
|
Request to Exit Switch (EX) Available for V40 Series exit devices to signal an alarm, send a remote signal, monitor egress, shunt power to an electromagnetic lock or other uses requiring a push pad contact switch.
|
|
 |
|
Request to Exit Switch Weatherized (EXxW) Available for V40 Series exit devices used on doors or gates that require a means of switching during egress in a moist, outdoor or other such application.
|